PreciMind Delta Check Intelligence System (PM-DCIS)

Compare two consecutive laboratory results using either a biological-variation-based reference change value (RCV) or a laboratory-defined delta threshold. Supports absolute, percentage, and rate-of-change rules with structured, non-numeric review.

Back

PM-DCIS supports two comparison approaches: biological-variation-based RCV (using shared CVi/CVa data) and laboratory-defined delta thresholds (absolute, percentage, or rate-of-change). RCV exceedance indicates the observed difference exceeds analytical and within-subject biological variation — it does not by itself establish clinical significance. Delta-check procedures require laboratory-specific design and validation.

Primary Inputs

Analytical & Biological CV

Enter CVi and CVa from an appropriate source (e.g. EFLM Biological Variation Database).

Comparability (optional)

These fields generate advisories, not automated clinical conclusions.

Critical-Value Rule (optional, separate from delta check)

A delta check and a critical-value alert are not the same. At least one limit required. Critical limits must use the same unit as the current result.

Serial Data Points (descriptive)

0 added

Add multiple time points for descriptive trend display. Multi-point trends are descriptive in this version.

Ready for analysis

Enter R1 and R2, select a comparison mode, then run the PM-DCIS analysis to receive a structured delta-check review, RCV assessment, and descriptive trend display.